Sign In | Join Free | My tjskl.org.cn
China Shenzhen Veikong Electric Co., Ltd. logo
Shenzhen Veikong Electric Co., Ltd.
Shenzhen Veikong Electric Co., Ltd.
Verified Supplier

4 Years

Home > Motor Soft Starter >

VKS-6000 The Latest Development of Motor Soft Starter for Overloaded Equipment

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

VKS-6000 The Latest Development of Motor Soft Starter for Overloaded Equipment

Brand Name : VEIKONG

Model Number : VKS6000

Certification : CE

Place of Origin : China

MOQ : 1

Price : Negotiable

Payment Terms : Western Union, T/T, L/C, D/A, D/P, PayPal

Supply Ability : 15000pcs per Month

Delivery Time : 3 days, depend on the order quantity

Packaging Details : Carton

Product Name : 45kw to 110kw Soft Starter

Voltage : 220v/380v

Output Frequency : 50/60Hz

Application : Fan,Motor,all kinds of 3 phase pumps,Industry,motor/pump/fan

Display : LCD

Protection class : IP20

Series : VKS6000

Brand : VEIKONG

Original : China

OEM : Support

Contact Now

45KW 55KW 75KW 90KW 110KW online soft starter for ac motor protection

Product description:

VKS-6000 is the latest development of online soft starter, is a new type of motor starting equipment developed by the international advanced level

based on power electronics technology, microprocessor technology and modern control theory and technology, which can effectively limit the starting voltage when starting the motor It can be widely used in overloaded equipment such as fans, pumps, conveyors and compressors. It is an ideal replacement for step-down starting equipment such as star / delta conversion, self-coupling buck and magnetron buck. No need to install a bypass contactor, greatly reducing user costs.

Key Feature

1, Six group parameters convenient in one soft starter to different power motors load.

2, Dynamic fault recording function and Inspecting motor feedback to realize closed loop control to give best motor start up in different conditions and different loads.

3, A variety of ways starting:voltage RAMP starting way can get the maximum output torque;Current limiting can realize biggest Limitations of the Start soft starting current.

4, Reliable quality Assurance:using computer simulation design;SMT Production process;Electromagnetic Compatibility Excellent.

Performance;High temperature aging,Vibration Test before delivery of the machine.

Product technical characteristics

Main circuit working voltage: AC380V (+ 10% ~ - 25%); Main circuit working current: 22A ~ 560A;

Main circuit frequency: 50Hz / 60Hz (± 2%); Soft start rise time: 2 ~ 60s;

Soft parking time: 0 ~ 60s; Current limit multiples: 1.5 ~ 5.0Ie; Initial voltage: 30% ~ 70% Ue; Cooling method: fan cooling;

Communication method: RS485 serial communication;

Installation easier

If the motor control center has limited space, using the compact design of the VKS-6000 saves 70% space, eliminates the need for bypassing the contactor, and reduces primary and secondary costs by more than 30%.

Stop smoother

The CPU also provides precise control of soft stops for applications that require smoother soft stops.

CPU for small inertia loads, such as pumps and conveyors, can greatly reduce or even eliminate the water hammer effect.

Debug faster

The VKS-6000 is easy to use at design time considering the ease of use menu is not surprising. After installation, the quick setup menu assists you in configuring the starter for common applications: it suggests a typical value that you can fine tune to your own needs, all with an easy-to-use dashboard.

Software innovation

A wider range of applications Built-in smart power motherboard, but Paul remote places, low voltage or voltage instability led to the device can not get up, intelligent power supply board can be within the voltage 150V- 460V application equipment to achieve the normal starting requirements.

New current-voltage coefficient, built-in power board can be directly calibrated current and voltage.

Start delay parameters, when the equipment power failure, the soft starter automatically delayed after 5 minutes

Technical Specification

Item

Description

Input Power Supply

Input Voltage

Three-phase 380V/480V/660 AC

Frequency

50/60Hz

Adaptive Motor

Squirrel-cage three-phase asynchronous motor

Starting Times

It is recommended not to exceed 20 times per hour.

Control Mode

(1) Operation panel control.

(2) Operation panel + external control.

(3) External control.

(4) External control + COM control.

(5) Operation panel + external + COM control.

(6) Operation panel + COM control.

(7) COM control.

(8) No start or stop operation.

Start Mode

(1) Current-limiting to start.

(2) Voltage ramp to start.

(3) Torque control + current-limiting to start.

(4) Torque control + voltage ramp to start.

(5) Current ramp to start.

(6) Voltage current-limiting double closed-loop start.

Stop Mode

(1) Soft stop.

(2) Free stop.

Protective Function

(1) Open loop protection for external instantaneous stop terminals.

(2) Over-heat protection for soft starter.

(3) Protection for too long starting time.

(4) Input open phase protection.

(5) Output open phase protection.

(6) Unbalanced three-phase protection.

(7) starting over current protection.

(8) Running overload protection.

(9) Under voltage protection for power voltage.

(10) Overvoltage protection for power voltage.

(11) Protection for fault parameter setting.

(12) Load short circuit protection.

(13) Auto restart or incorrect wiring protection.

(14) Incorrect wiring protection of external control stop terminals.

Ambient

Place to be used

Indoor location with good ventilation free from corrosive gas and conductive dust.

Altitude

Below 1000M. It have to rise the rate power when the altitude is more than 1000M.

Temperature

-20 +45 C

Humidity

90%RH without dew condensation.

Vibration

<0.5G

Structure

Protection Class

IP20

Cooling Pattern

Fans cooling.

Product Application

VKS-6000 The Latest Development of Motor Soft Starter for Overloaded Equipment
VKS-6000 The Latest Development of Motor Soft Starter for Overloaded Equipment

VKS-6000 The Latest Development of Motor Soft Starter for Overloaded Equipment


Product Tags:

IP20 110 Kw Soft Starter

      

IP20 soft start motor controller

      

Ac Motor 75 kw soft starter

      
Quality VKS-6000 The Latest Development of Motor Soft Starter for Overloaded Equipment for sale

VKS-6000 The Latest Development of Motor Soft Starter for Overloaded Equipment Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Veikong Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)